Russia ERA-GLONASS Certification Standards, Test Items & Applicable Products

2026-05-07

ERA-GLONASS is Russia’s mandatory in-vehicle emergency call system, tightly bound with GLONASS satellite navigation. It works independently and is incompatible with EU eCall.

1. Mandatory Implementation Timeline

Fully enforced in 2017 by batches for different vehicle categories; all compliant models must pass certification to enter Eurasian market in 2026.

  2. Eurasian Union Regulatory Framework

·Top regulation: TR TS 018/2011 Wheeled Vehicle Safety

·EMC reference: UN R10

·Russian reference standards: GOST R 55531, GOST R 55532, GOST R 55534 (for test method only, not mandatory regulatory documents)

  3. Mandatory Vehicle Types

Mandatory for M1 passenger cars (≤9 seats) and N1 light commercial vehicles (≤3.5 tons). M2/M3 buses and N2/N3 heavy trucks have exemption and phased implementation clauses. All fuel types (gasoline, diesel, EV) are compliant with no exemption.

  4. Core Differences Between ERA-GLONASS and EU eCall

·Navigation: ERA-GLONASS mandates GLONASS (GPS auxiliary); EU eCall adopts GPS/Galileo with no GLONASS requirement

·Vehicle scope: ERA-GLONASS covers wider vehicle categories

·Technical details: Different MSD data format and Russian exclusive frequency bands

·Certification system: Two independent systems with no mutual recognition

  5. Network & Communication Technology

Modern ERA-GLONASS supports 4G LTE, compatible with 2G/3G for remote area coverage. IP data transmission gradually replaces traditional SMS as the mainstream.

  6. Core ERA-GLONASS Test Items

·Function Test: Automatic/ manual emergency trigger, MSD data integrity, voice call stability

·Positioning Performance: Mandatory GLONASS support, cold start time, positioning accuracy and signal sensitivity

·Communication Performance: Call success rate, network switching stability and Russian frequency band adaptation

·EMC Test: UN R10 standard (radiation emission/immunity, ESD)

·Environmental Reliability: Temperature range -40℃~85℃, humidity, vibration and mechanical shock test

·Electrical Performance: Voltage fluctuation protection, reverse voltage and overvoltage protection


For Russia ERA-GLONASS certification, contact Blueasia Testing & Certification Consultant: 13534225140